ȸ»ç¼Ò°³ Á¦Ç°¼Ò°³ °í°´Áö¿ø Á¤º¸¸¶´ç ±â¼úÀÚ·á½Ç
 
ÈÞ´ë¿ë/½ÇÇè½Ç¿ë ÃøÁ¤±â
pH/ISE Meter
DO Meter
Conductivity Meter
Multi Meter
MLSS/Źµµ/ÀÜ·ù¿°¼Ò ÃøÁ¤
¼öÁú´ÙÇ׸ñÃøÁ¤±â
ÁöÇϼö ÀÚµ¿°üÃø¸Á ÃøÁ¤±â
BOD ÈÞ´ë¿ë
COD ÃøÁ¤±â
¼öÁú TMS
ÇöÀ弳ġ¿ë ÄÁÆ®·Ñ·¯
pH/ORP
DO
EC (Àüµµµµ/¿°µµ/ÀúÇ×)
Ion (ISE)
Źµµ / SS / MLSS
ÀÜ·ù¿°¼Ò / ¿ÀÁ¸
Ŭ·Î·ÎÇÊ / ³²Á¶·ù
¸ÖƼ
¾Ç¼¼»ç¸®
Àü±Ø & ¾Ç¼¼»ç¸®
Electrode
Accessories
ISE Electrode
¾Ï¸ð´Ï¾Æ¼ºÁú¼Ò ÀÌ¿Â Kit
Áú»ê¼ºÁú¼Ò ÀÌ¿Â Kit
Çì¹ÐÅÏ
Hamilton »ê¾÷¿ë ¼¾¼­
Hamilton Sensor
ARC µðÁöÅÐ ¼¾¼­
>> Á¦Ç°¼Ò°³ >> ¿Â¶óÀÎÀÚµ¿¼öÁúºÐ¼®±â >> pH,DO,EC Controller >> pH
 
pH Controller pH-915
¼³¸í

- pH Electrode¿Í Pt100 ¿Âµµ¼¾¼­ ÀÔ·Â
- pH°ª, ¿Âµµ°ª, °¢Á¾ ¼³Á¤°ª, Set-point »óÅ ǥ½Ã
- ÀÚµ¿ ¶Ç´Â ¼öµ¿ ¿Âµµº¸Á¤±â´É ¹× ¹öÆÛ ¿ë¾× ÀÚµ¿ÀνÄ
- On/Off Á¦¾î ¹× P Á¦¾î °¡´É- 4~20mAÃâ·Â

 
 
 

- One-MicrochipÀ» ÀÌ¿ëÇÑ Microprocessor ¹æ½Ä
- pH Electrode¿Í Pt100 ¿Âµµ¼¾¼­ ÀÔ·Â
- pH ÃøÁ¤°ª, ¿Âµµ°ª, °¢Á¾ ¼³Á¤°ª, Set-point »óÅ ǥ½Ã
- ÀÚµ¿ ¶Ç´Â ¼öµ¿ ¿Âµµ º¸Á¤ ±â´É ¹× ¹öÆÛ ¿ë¾× ÀÚµ¿ÀνÄ
- On/Off Á¦¾î ¹× P Á¦¾î °¡´É- 4~20mAÃâ·Â, RS485 Ãâ·Â°¡´É(¿É¼Ç)

 

 

Model No.

pH-915

pH ÃøÁ¤

pH ÃøÁ¤¹üÀ§

0.00 ~14.00 pH

ºÐÇØ´É

0.01pH

Slope

59.16mV/pH 25¡É 80~110%, pH7.00¿¡¼­ mV °ª : 0.0

Relative Accuracy

¡¾0.02pH (À¯¸®Àü±Ø, Ç¥ÁØ¿ë¾× ±âÁØ)

Repeatability

¡¾0.05pH

¿Âµµ ÃøÁ¤

¿Âµµ ÃøÁ¤ ¹üÀ§

0.0 ~ 100.0¡É

ºÐÇØ´É

0.1 ¡É

Temperature Drift

Zero and Span : <0.03% of span per ¡É

Á¦¾î Ãâ·Â

- Ãâ·Â ¸±·¹ÀÌ ¼ö : 2°³
- Ãâ·Â ±Ô°Ý : SPDT Á¢Á¡2(Á¦¾î¿ë)
- ½ºÀ§Äª Àü¾Ð ¹× Àü·ù : AC220V/3A

- Ãâ·Â ±â´É : Control (°¢°¢ÀÇ ¸±·¹À̸¶´Ù µ¶¸³ÀûÀ¸·Î ±â´É ¼³Á¤ °¡´É)
- Control ±â´É : On/Off Á¦¾î ¶Ç´Â ºñ·Ê Á¦¾î(PFM/PWM)

½ÅÈ£ Ãâ·Â

- ¾Æ³¯·Î±× Ãâ·Â ¹üÀ§ : 0/4 ~ 20mA(Àý¿¬)
- ¹ÝÀÀ½Ã°£ : 2.5s for 98% - Isolation : 250 Vac
- Load : Max 550 ¥Ø-
RS485 Ãâ·Â °¡´É
- RF Ãâ·Â °¡´É (Option)

¼¾¼­ º¸Á¤

- ¼¾¼­ º¸Á¤¹æ¹ý : 2Á¡ ÀÚµ¿ ±³Á¤, 2Á¡ ¼öµ¿ ±³Á¤

Hold ±â´É

- ¼¾¼­ ±³Á¤ ½Ã Auto Hold - ¾Æ³¯·Î±× Ãâ·Â : Á÷Àü Ãâ·Â °ªÀ¸·Î Hold

»ç¿ë ȯ°æ

- ÀÛµ¿ ¿Âµµ : 0/50¡É - ÀÛµ¿ ½Àµµ : 35~85% (ÀÀ°á ¾øÀÌ)

±â ±¸

- ÃëºÎ¹æ¹ý : Panel Mounting
- Case ÀçÁú : Flame-resistant resin
- ¿ÜÇüÄ¡¼ö : 48 x 96 x 110 mm (HxWxD)
- ¹«°Ô : 0.5 kg

Àü ¿ø

- Àü¿ø°ø±Þ : AC 100 ~ 240V, 50/60Hz
- ¼ÒºñÀü·Â : ÃÖ´ë 5VA - DC 24V (Option)

 

1) Standard
   - Instruction Manual
  
(2) Option
   - pH Electrode
   - ATC Probe
   - pH Buffer Solution (pH4,7,10 125ml or 475ml)
   - ħÀûÇü Ȧ´õ (Ç¥ÁØÀçÁú: Polypropylene, ±æÀÌ :1m or 2m, Áö¸§:  34¥Õ
                   ÀçÁú±âŸ: P.P, PVC, STS¿Ü)

   - ºê¶óÄÏ('L' Rack Mount, Screw Mount¿Ü)
   - À¯ÅëÇü Ȧ´õ
   - Áß°è¹Ú½º & ¿¬Àå Cable(10~20m)
   - ÆßÇÁ

   - ¼¼Á¤ÀåÄ¡ (Air, Water-Jet, Ultrasonic)